Wiring Diagram For Fire Pump
Wiring from the fire pump controller to the fire pump motor not installed through a building as covered in 6956b must be in rigid metal conduit intermediate metal conduit electrical metallic tubing liquidtight flexible metal conduit liquidtight flexible nonmetallic conduit type b listed type mc cable with an impervious covering or.
Wiring diagram for fire pump. Electrical wiring shall be typically sized to carry at least 125 of the full load current of the pump motor. 21331 ec mod. By mike holt for ecm magazine. Three phases variable speed pressure maintenance controller.
In a standard application not fire pump you are required to connect this terminal to jc 9 and to the dwl terminal of the belt alternator. Y 07x 170 x flow expressed as a percentage of rated flow y pressure created by the pump net pressure expressed as a percent of rated pressure 93. If you work with the connections or controls for fire pumps you need to understand article 695. The electrical wiring between power sources and fire pump controller shall meet the nfpa 20 chapter 9 3 article 695 national electrical code section c c221 canadian electrical code section 32 200 or other local codes.
Article 695 fire pumps. This diagram shows the main features of fire pump house installations these will vary depending upon the number and types of pumps to be installed and they will be placed to suit the position of main pipe runs etc. Guide to the installation and operation of fire pumps 25. Find all fire pump controller drawings as well as jockey pump controller remote alarm panel and low suction shutdown controller drawings here.
Today you can expect to find a fire pump in almost any public building or factory. You can adjust the default setting in the parameter crank vdc see section 1303. Fire pump controller wiring diagram. Options and miscellaneous.
Variable speed jockey pump controller. Within enclosed construction dedicated to the fire pump circuits with minimum 1 hour fire resistive rating circuit protective systems with a minimum 1 hour fire resistance installed per manufacturers instructions generator control wiring methods between fire pump transfer switch and generator. Fire and jockey pump controller sensing lines mike trumbature with regard to fire pump wiring diagram image size 797 x 612 px and to view image details please click the image. Here is a picture gallery about fire pump wiring diagram complete with the description of the image please find the image you need.